Written by admin on July 28, 2022 in News

Supplying Caterpillar CG170-20
New 2000kW Caterpillar CG170-20 Natural Gas gensets OR
Natural gas genset MWM TCG2020V20 50Hz 2000 kW
Cummins brand diesel generators
All the details that you may need for being certain about your correct MWM diesel generator are as
follow:
Natural gas Genset MWM TCG2020V20 50Hz 2000 kW 10,5 kV (Same engine as a caterpillar with
CG170-20 Cat model)
Description Genset
Base engine TCG 2020 V20 50Hz
Standard alternator n = 1,500 / min
Base genset 50Hz, 2MV, Marelli MJH 630 LA4 10500V
Exhaust manifold with Exhaust waste gate, manifold 90° vertical
Standard conservation (24 months)
Exhaust turbocharger
Base frame without oil tank, 230/400 V pre-lubrication
Combustion air filter without preheating TCG 2020
Suctions System
Spare parts for commissioning MWM
Base system ТЕМ
Operating terminal (BRT)
Intelligent selection unit, basis system (IAEBS)
Connection parts for 2 ТЕМ cabinets without option "failure indication system" (IAEST)
ТЕМ control cabinet, packaging, cables
genset test without customer participation
Standard documentation (2 copies) incl. preparation
Main technical data:
Power KW 2000 KW
Power Output 1983 KW RPM1500 Fuel Natural Gas Generator Model
Alternator: Marelli MJH 630 LA4 Volts 10500 Hz 50 Year of Manufacturing 2018
Total Running Hours 0
Equipment in its original packaging.
Attached original Scope of Supply and original technical specifications
Natural gas genset MWM TCG2020V20 50Hz 2000 kW 10,5 kV
(Same engine as CG170-20 Cat model)
Description
Genset
Base engine TCG 2020 V20 50Hz
Standard alternator n = 1,500 / min
Base genset 50Hz, 2MV, Marelli MJH 630 LA4 10500V
Cooling type (HE, KC, or RC), 50Hz/1500RPM or 60 Hz/1800 RPM
Natural gas Genset MWM TCG2020V20 50Hz 2000 kW 10,5 kV (Same engine as CG170-20
Cat model)
Power Output 1983 KW RPM1500 Fuel Natural Gas Generator Model
Alternator: Marelli MJH 630 LA4 Volts 10500 Hz
We have Cummins lean-burn gas engines QSV91G in stock with zero run hours due to a canceled
project
1450kW – 6.3kV – 50Hz lean burn  (flare gas but suitable to run NG)

Gen-set comes with muffler – cooler – controller PCC3.3 – gas street
Specification sheet
Natural gas generator set QSV91 series engine 1540 kW – 2000 kW
Description
Cummins lean burn gas generator sets are fully integrated power generation systems utilizing
state-of-the-art technology that results in optimum performance and efficient use of fuel for
standby and continuous duty, CHP, and peaking applications.
Features
Cummins® heavy-duty engine – Rugged 4-cycle lean burn gas combustion engine utilizing full
authority electronic engine management and monitoring.
Exhaust emissions- Learning burn technology provides exhaust emissions levels as low as 250
mg/Nm3 (0 5 g/hp hr) NOx
.
Fuel Flexibility – Ability to run on natural gas as well as alternative gaseous fuels with lower BTU
properties and varying Methane Numbers (MN)
.
Permanent magnet generator (PMG) – Offers enhanced motor starting and fault clearing short
circuit capability.
Alternator – Several alternator sizes offer selectable voltage and temperature rise with low
reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing
short-circuit capability, class F or H insulation (see Alternator Data Sheet for details), bearing
and stator RTDs and anti-condensation heater. Mechanically strengthened for use on utility
paralleling with the unreliable grid.
Control system – The Power Command 3.3 generator set control is standard equipment and
provides total Genset system integration including full paralleling capability in grid or load share
mode, precise frequency and voltage regulation, alarm and status message display, AmpSentry™
protection, output metering, auto-shutdown at fault detection and a user interface panel
installed onto the Genset. Optional grid code compliant control systems and remote operator
panels are also available on select models.
Cooling system – The generator set is equipped with the capability of interfacing with a remote
radiator or heat exchanger
Warranty and service – Backed by a comprehensive warranty and worldwide distributor
A network that can provide all levels of service from replacement parts to performance
guarantee programs.
Base load (continuous) power (COP)definition
Applicable for supplying power continuously to a constant load up to the full output rating for
unlimited hours. No sustained overload capability is available for this rating. Consult authorized
distributor for rating. (Equivalent to Continuous Power in accordance with
ISO 8528, ISO 3046, AS2789, DIN 6271, and BS 5514).
NATURAL GAS GENSET – MWM TCG2020V20 50Hz 2000 kW, * For natural gas applications (NOx <=
500 mg / Nm3 *) * Power data at 50 Hz , 2.000 kWe * Warranty: 24 months or 16.000 running hours
(what happens before), but no longer than 30 months after manufacture

Item description
Gen Set MWM TCG 2020 V20 50Hz NG with integrated oil tank and TEM
Power cabinet 400V, 4000A + Connecting cable about 10 m
Modul control cabinet, with installed TEMP EVO
Connection cables, Cable shelves, Generator connection Power cable about 10 m + Nickel-plated
brass seals
Another equipment:
Oil refill tank with pump
Plate heat exchanger M10-BFM Alfa Laval (2018)
Gas collector with pressure regulator and filter
Cooler
Circulation pump (cooler) with control valves
Flue gas condenser
Circulation pump (heat)
Chimney (Stainless steel) with damper
Chimney metal construction 15 m
Air intake (galvanized sheet metal)
Air outlet (galvanized sheet metal)
Special agents commission

Caterpillar CG170-20 tedarikinde profesyoneliz
Yeni 2000kW Caterpillar CG170-20 Doğal Gaz jeneratörleri VEYA
Doğalgazlı jeneratör MWM TCG2020V20 50Hz 2000 kW
hatta Cummins marka dizel jeneratörler

Leave Comment